Model No.: YF-B090
Brand: YUKA
Material: Aluminum Alloy
Housing Serve Lige: 15 Years
Element Serve Life: 6000~8000 Hours
Maxi. Operate Pressure: 1.6 Mpa
Operate Temperature: 1.5~80ºc
Connection: Rc2"
Filtration Performance: From 5 μm To 0.01μm
Resistance Corrosion: Inside And Outside
Filter Type: Coalescing
Option Parts: Connection Kit
Configuration: Manual Ball Valve
Element Top Cap: Diversion Fin Less Pressure Loss
Element Top Cap Color: Colorful To Distinguish
Color: Light Blue
Transport Package: Brown Inner Box & Cardboard
Specification: Dimension: 174 X 142x 558mm
HS Code: 8421399090
Clapboard: Without Clapboard
Filter Number: 1
Medium Material: Fiberglass
Filtration Grade: Medium Filter
Type: Cartridge Filter
Efficiency: F9
Brand: Yuka
Flow Rate: 10 M³/Min
Selling Units | : | Piece/Pieces |
Package Type | : | Internal Box & External Carton |
Picture Example | : |
Installation method of Compressed Air Filter
①Install and use within the specified working pressure and working temperature range, and install all levels of filters in the correct order according to the air inlet and outlet instructions or the direction indicated by the arrow, from coarse to fine installation. Avoid bypass as much as possible during installation. Because the oil in the air is bypassed to the downstream of the filter and then sticks to the inner wall of the pipeline, it is difficult to find effective means to remove it.
②The Filter Element should be replaced regularly. When replacing the filter element, use an Allen wrench to unscrew the four screws of the lower cover and take out the old filter element from below. Carefully record the replacement time. It is recommended that the working time z should not exceed 8000 hours.
③The discharge time of the auto drain is suitable for draining the liquid water, and the discharge interval is subject to the water content in the pipeline;
④Different grades of compressed Air Filters can be equipped with electronic drain valves or manual valves according to customer requirements.
PF | AO | AA | AX | ACS | AR | AAR |
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible | High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w). | High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w) | Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w) | Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w) | Dust particles whose diameter more than 1μm can be removed | Dust particles whose diameter more than 0.01μm can be removed |
Product are test with the international advanced testing equipment based on standard ISO12500, Which is equivalent to the standard ISO8573.1-2010 quality standard, and provide filter performance test report.
Filtration Grade PF AO AA AX ACS AR AAR Size of solid particles(ISO12500-3) 5μm 1μm 0.01μm 0.01μm - 1μm 0.01μm Filtration performance of solid particles(ISO12500-3) - 99.999+% 99.999+% 99.999+% 99.999+% 99.999+% 99.999+% Filtration performance of oil(ISO12500-1) 50% 80+% 99.9+% 99.99+% - - - Residual oil content(ISO12500-1) 5mg/m³ 0.6mg/m³ <0.01mg/m³ <0.001mg/m³ <0.004mg/m³ - -
Product Picture
Model | Pipe size | Flow rates | Dimension (mm) | |||||||
L/S | m³/min | scfm | W(Width) | D(Depth) | H (Height) | A | B | C(clearance for housing) | ||
YFB010 | RC1/2" | 16.7 | 1.0 | 35.5 | 96 | 79 | 252 | 29 | 223 | 118 |
YFB020 | RC3/4" | 25.0 | 1.5 | 53.0 | 96 | 79 | 252 | 29 | 223 | 118 |
YFB030 | RC3/4" | 30.0 | 1.8 | 63.6 | 96 | 79 | 286 | 29 | 257 | 153 |
YFB040 | RC1" | 33.3 | 2.0 | 71.0 | 96 | 79 | 286 | 29 | 257 | 153 |
YFB060 | RC1" | 60.0 | 3.6 | 127.0 | 138 | 111 | 357 | 37 | 320 | 208 |
YFB070 | RC1" | 83.3 | 5.0 | 177.0 | 138 | 111 | 458 | 37 | 421 | 303 |
YFB080 | RC1-1/2" | 125.0 | 7.5 | 265.0 | 138 | 111 | 458 | 37 | 421 | 303 |
YFB090 | RC2" | 166.7 | 10.0 | 353.1 | 174 | 142 | 558 | 58 | 500 | 467 |
YFB100 | RC2-1/2" | 216.7 | 13.0 | 459.0 | 174 | 142 | 558 | 58 | 500 | 467 |
YFB110 | RC2" | 283.3 | 17.0 | 600.0 | 174 | 142 | 838 | 58 | 780 | 794 |
YFB120 | RC2-1/2" | 316.7 | 19.0 | 671.0 | 174 | 142 | 838 | 58 | 780 | 794 |
YFB130 | RC3" | 416.7 | 25.0 | 883.0 | 220 | 184 | 645 | 74 | 571 | 514 |
YFB140 | RC4" | 466.7 | 28.0 | 989.0 | 220 | 184 | 645 | 74 | 571 | 514 |
YFB150 | RC3" | 683.3 | 41.0 | 1448.0 | 220 | 184 | 902 | 74 | 828 | 764 |
YFB160 | RC4" | 800.0 | 48.0 | 1695.0 | 220 | 184 | 902 | 74 | 828 | 764 |
Technical requirements | Maximum operating pressure: 16 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C |
Pressure | Barg | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 59 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |