Eliminate Particles Dust/ Oil Vapor By Air Filter
$2471-19 Piece/Pieces
$234≥20Piece/Pieces
Payment Type: | T/T,L/C |
Incoterm: | FOB,EXW,CIF,CFR |
Transportation: | Ocean,Land,Air,Express |
Port: | Shenzhen,Ningnbo,Qingdao |
$2471-19 Piece/Pieces
$234≥20Piece/Pieces
Payment Type: | T/T,L/C |
Incoterm: | FOB,EXW,CIF,CFR |
Transportation: | Ocean,Land,Air,Express |
Port: | Shenzhen,Ningnbo,Qingdao |
Model No.: YD080
Brand: YUKA
Origin: China
Element Serve Life: 6000~8000 Hours
Clapboard: Without Clapboard
Filter Number: 1
Medium Material: Fiberglass
Type: Cartridge Filter
Material: Aluminum Alloy
Housing Serve Lige: 15 Years
Filtration Performance: From 5 μm To 0.01μm
Maxi. Operate Pressure: 1.0mpa
Operate Temperature: 1.5~80ºc
Resistance Corrosion: Inside And Outside
Parts: Dp Indicator, Auto Drain, Sight Glass
Transport Package: Brown Inner Box & Cardboard
Filtration Grade: Medium Filter
Connection: Rc1"
Efficiency: F9
Diversion Fin Design On Element Top Cap: Less Pressure Loss
OEM & ODM Service: Yes
Flow Rate: 4.8m³/Min
Pressure Loss: About 0.25 Bar
Bleed Valve: Available
Specification: Dimension:120 X 110 X 477mm
Selling Units | : | Piece/Pieces |
Package Type | : | Carton Package |
Picture Example | : |
The file is encrypted. Please fill in the following information to continue accessing it
The primary reason for using a Compressed Air Filter is to remove contaminate and improve air quality. Let’s take a look at the different types of air filters and the questions that will help you choose the correct filter.
①Assess the requirements of your application. Different industry require different solution. | ③Any specific micron of filtration performance you required? | |||||||
②What type of filtration is needed? Coalecent filter material removes solid and liquied contaminants from gas streams. Particulate filter media removes solid from gas streams. Absorber media removes hydrocarbon vapors from gas streams. | ||||||||
④What are the working conditions of your application? Mainly criteria of consider : Flow, working pressure, temperature,pressure loss,material of structure (stainless steel, aluminum alloy, mild steel, carbon steel) | ||||||||
⑤Filter flow rate from how much SCFM? Pressure drop should be less than **bar? For saving the cost and protect environment. | ||||||||
2. 6000~8000 hours spanlife for filter element,filtering performance up to 99.99%
3. Integrated die-casting filter up to 3 inch, flow rate up to 37.2m³/min.
4. Alternative for Domnick Hunter Oil X Plus Series.
5. Configuration: Differential pressure indicator, sight glass, auto drain.
Filter Element Grade
Filtration Grade
PF AO AA AX ACS AR AAR Particle removal (ISO12500-3) 5μm 1μm 0.01μm 0.01μm - 1μm 0.01μm Outlet oil aerosol concentration (ISO12500-1) 5mg/m³ 0.6mg/m³ <0.01mg/m³ <0.001mg/m³ <0.004mg/m³ - - Filtration performance of Particle (ISO12500-3) - 99.999+% 99.999+% 99.999+% 99.999+% 99.999+% 99.999+% Filtration performance of (ISO12500-1) 50% 80+% 99.9+% 99.99+% - - - Element spanlife 6000 hours 6000 hours 6000 hours 6000 hours 2000-3000 hours 4000-6000 hours 4000-6000 hours Precede with Before Refrigerated Air Dryer after air dryer after AO after AA before AX after desiccant dryer after AR
Model Pipe size Flow rates Dimension (mm) L/S m³/min scfm W(Width) D (Depth) H (Height) A B C(clearance for housing) YD017 RC1/2" 16.7 1.0 35.3 89 79 246 40 186 118 YD025 RC3/4" 25.0 1.5 53.0 89 79 246 40 186 118 YD030 RC1/2" 30.0 1.8 63.6 89 79 280 40 220 158 YD035 RC3/4" 33.3 2.0 70.6 89 79 280 40 220 158 YD058 RC3/4" 46.7 2.8 98.9 120 110 377 55 276 195 YD068 RC1" 60.0 3.6 127.1 120 110 377 55 276 195 YD080 RC1" 80.0 4.8 169.5 120 110 477 55 377 290 YD145 RC1-1/2" 120.0 7.2 254.2 120 110 477 55 377 290 YD220 RC2" 200.0 12.0 423.7 162 151 676 64 566 480 YD260 RC2-1/2" 233.3 14.0 494.4 162 151 676 64 566 480 YD330 RC2" 267.2 16.0 564.8 162 151 984 64 875 780 YD360 RC2-1/2" 317.3 19.0 670.7 162 151 984 64 875 780 YD405 RC2-1/2" 367.4 22.0 776.6 200 189 757 78 634 560 YD430 RC3" 467.6 28.0 988.4 200 189 757 78 634 560 YD620 RC3" 620.0 37.2 1313.6 200 189 1012 78 889 780 Technical requirements Maximum operating pressure: 10 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C
Pressure | Barg | 1 | 2 | 3 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |